| Specification Attribute | Technical Detail |
| Brand | Smarten |
| Series / Range | Bravo Series |
| Model / Item Designation | BRAVO 10000 |
| Product Type | Heavy-Duty Pure Sine Wave Commercial UPS / Inverter |
| Generic / Common Name | 120V Central UPS / 10 kVA Inverter / Heavy Commercial Backup Station |
| Power Rating | 10000 VA (10 kVA) |
| Operating DC Voltage | 120 V DC (Requires 10 x 12V Batteries in Series) |
| Output Waveform | Pure Sine Wave (Noiseless, Motor & Electronic Safe) |
| Output Voltage & Frequency | 220 V AC ± 10% | 50 Hz ± 0.2 Hz |
| Input Frequency Range | 40 Hz – 60 Hz |
| Charging Current | 15 Amps (Faster Battery Charging) |
| Low-Voltage Charging Capability | Active Smart Charging Down to 90V Mains Input |
| Discharge Current at Full Load | 66 A ± 2 A |
| Float Charging Voltage | 137 V ± 0.4 V |
| Low Battery Indication | 108 V ± 0.4 V |
| Battery Compatibility | Lead-Acid (LA), Tall Tubular & Sealed Maintenance Free (SMF) |
| Circuit Protection Systems | Back-feed Protection, Phase-to-Phase Isolation, Short-Circuit, Overload & Low Battery Cutoff |
| Unit Dimensions (L x W x H) | 575 x 415 x 640 mm |
| Unit Weight | 75 kg |
| Target Power Systems | Commercial Complexes, Multi-Story Buildings, Healthcare Facilities & Data Centers Across Nepal |
| Best Used For | Central ACs, Industrial Water Pumps, Cold Storage, Server Racks & Whole-Facility Central Power Backup |
Massive 10000VA (10 kVA) Pure Sine Wave Capacity: Supplies clean, undistorted 220V AC electricity capable of operating commercial HVAC setups, water pumps, cold rooms, and IT server networks without electrical hum or thermal strain.
Heavy-Duty 120V High-Voltage DC Architecture: Utilizes a 10-battery series configuration (10 x 12V), sustaining 66A ± 2A full-load current while significantly reducing heat loss and line resistance across long operating runs.
Rapid 15A Charging with 90V Low-Voltage Support: Employs an intelligent charging circuit providing a continuous 15 Amp current for fast recovery, actively charging battery arrays even during severe grid drops down to 90V.
Phase-to-Phase & Back-Feed Protection: Integrated hardware circuitry guards the system against accidental phase-to-phase line surges, dangerous back-feeding, short circuits, and thermal overloads.
Calibrated Battery Lifespan Management: Regulates float charging at 137V ± 0.4V with an automated 108V ± 0.4V low-battery warning threshold to prevent over-discharge in tubular, flat plate, and SMF batteries.